Single inlet centrifugal fan
MN 554/230V + BTRN-1-2 + RNFLA554
MN554 = fan
230V = supply 1ph
BTRN = speed controller
RNFLA = inlet flange
|
|
| MN202/220V | 56М2 | 0.09 | MN202/380V | 56М2 | 0.09 | | MN252/220V | 56М2 | 0.09 | MN252/380V | 56М2 | 0.09 | | MN302/220V | 63М2 | 0.18 | MN302/380V | 63М2 | 0.18 | | MN304/220V | 63A-4 | 0.12 | MN304/380V | 63A-4 | 0.12 | | MN402/220V | 63М2 | 0.25 | MN402/380V | 63М2 | 0.25 | | MN404/220V | 63A-4 | 0.12 | MN404/380V | 63A-4 | 0.12 | | MN502/220V | 71М2 | 0.37 | MN502/380V | 71М2 | 0.37 | | MN504/220V | 63М4 | 0.18 | MN504/380V | 63М4 | 0.18 | | MN552/220V | 71М2 | 0.55 | MN552/380V | 71М2 | 0.55 | | MN554/220V | 63М4 | 0.18 | MN554/380V | 63М4 | 0.18 | | MN602/220V | 80М2 | 1.1 | MN602/380V | 80М2 | 1.1 | | MN604/220V | 71М4 | 0.25 | MN604/380V | 71М4 | 0.25 |
Attention
- The MN fan may never be used with free inlet. There should be a minimal counter-pressure as shown in the table above. Please measure the current at first startup.
- The motorspeed is not adjustable by means of an electronic controller.
Dimensions
|
|
| MN202 | 85 | 120 | 85 | 62 | 190 | 168 | 70 | 60 | 85 | 75 | 93 | 90 | 7 | 110 | 105 | 39 | 223 | 2.5 | | MN252 | 112 | 150 | 100 | 94 | 270 | 223 | 82 | 85 | 110 | 110 | 128 | 128 | 7 | 140 | 140 | 44 | 232 | 3 | | MN302 | 112 | 150 | 100 | 94 | 270 | 223 | 85 | 85 | 110 | 110 | 128 | 128 | 7 | 140 | 140 | 47 | 270 | 5.5 | | MN304 | 130 | 150 | 102 | 96 | 260 | 220 | 85 | 85 | 105 | 110 | 115 | 119 | 7 | 126 | 128 | 46 | 285 | 5,5 | | MN402 | 112 | 150 | 100 | 94 | 270 | 223 | 110 | 85 | 128 | 103 | 138 | 115 | 9 | 155 | 130 | 60 | 295 | 6 | | MN404 | 130 | 150 | 102 | 96 | 260 | 220 | 85 | 85 | 110 | 110 | 115 | 119 | 7 | 130 | 150 | 57 | 305 | 5,5 | | MN502 | 122 | 195 | 120 | 115 | 322 | 273 | 110 | 110 | 128 | 128 | 140 | 140 | 9 | 160 | 160 | 60 | 318 | 9.5 | | MN504 | 122 | 195 | 120 | 115 | 322 | 273 | 110 | 110 | 128 | 128 | 140 | 140 | 9 | 160 | 160 | 60 | 295 | 6 | | MN552 | 158 | 195 | 120 | 115 | 322 | 273 | 110 | 110 | 128 | 128 | 140 | 140 | 9 | 160 | 160 | 60 | 318 | 10 | | MN554 | 158 | 195 | 120 | 115 | 322 | 273 | 110 | 110 | 128 | 128 | 140 | 140 | 9 | 160 | 160 | 60 | 295 | 7 | | MN602 | 180 | 222 | 156 | 145 | 405 | 338 | 140 | 140 | 160 | 160 | 170 | 170 | 9 | 190 | 190 | 77 | 385 | 20 | | MN604 | 180 | 222 | 156 | 145 | 405 | 338 | 140 | 140 | 160 | 160 | 170 | 170 | 9 | 190 | 190 | 77 | 335 | 12 |
Air performance
Notes
Pt = Total pressure
Ps = Statical pressure
Pv = Absorbed power
P[W]/P[kW] = Motor power
Qv = Air flow rate
T = 15°C
P = 1 atm
Attention
- At the orientation drawing, the motor is directed towards you. The desired orientation has to be specified upon order.
|